BC Biomedical SA-2001 Manual do Utilizador Página 16

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 65
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 15
Defibrillator Analyzers
Defibrillator Analyzers
Defibrillator Analyzer
Defibrillator Analyzer
Features
Features
-
-
DA-2006 Series
DA-2006 Series
Biphasic & Monophasic Compatible
Fully AED Compatible
Graphical Display with Backlighting &
Simultaneous Details of Parameters with
Scrolling Option Control
On-Screen Viewing of Defib & Pace
Waveforms
5000 V, 1000 Joule Capacity
High & Low Ranges
Cardioversion Delay Measurement
Charge Time Measurement
Waveform Storage & Playback
10 AHA & European Color Coded
Universal Patient Lead Connectors
25 Pin Connector for Centronics Printer
Power, two 9 V Batteries (Battery
Eliminator Furnished)
Low Battery Indicator
Flash Programmable, Field Upgradeable
Auto Sequence Testing
PC Utility Software for Auto Sequence
Development & Maintenance
Storage for 50 Custom Sequences
Features - DA-2006P
Features - DA-2006P
26 Selectable Internal Loads
Full Pulse Analysis
On-Screen Viewing of Pace Waveform
Demand Sensitivity Test
Refractory Period Tests
50/60 Hz Interference Test Signals
Pacer Input Defib Protection
DA-2006P
DA-2006P
The DA-2006 and DA-2006P Defibrillator
Analyzer Series take advantage of the latest
electronic technology and deliver accurate,
consistent test results on all defibrillators,
regardless of manufacturer or model.
Whether you need to test output energy,
cardioversion delay time, maximum energy
charge time, or test your AED, the DA-2006
and DA-2006P deliver. You can even capture
and view the actual output energy and pacer
waveforms to check for any abnormalities.
With 26 internal test loads, the DA-2006P
delivers a full range of capabilities for testing
the Transcutaneous Pacemaker function of
your advanced level defibrillators, including
tests like demand sensitivity, refractory
period, rate, pacer pulse width, pacer pulse
amplitude, etc. Test pacer functionality with
the peace of mind that the Pacer Input
terminals on the DA-2006P are internally
protected against accidental defibrillator
discharge.
The DA-2006 & DA-2006P offers automated
testing. Create and store up to 50 unique
testing “auto sequences”, including both
defibrillator and pacer tests. You can easily
edit existing sequences and create new ones
with our unique PC-based utility software.
You can also “clone” a specific set of auto
sequences to multiple analyzers.
13
13
1-888-223-6763 - bcgroupintl.com
1-888-223-6763 - bcgroupintl.com
Vista de página 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 64 65